Go To Beryllium Treatment Disclosure Policy
Enhancement Disclosure Policy Adjusted after September 2004
| Clarity Enhanced by |
Fissure Healing with or without Borax (Residues) |
Fissure Healing with or without Borax and/or glass filling in fissures/cavities |
Amount of Residues in Fissures |
very minor |
minor |
moderate |
prominent |
| GRS Residues Grading (*) |
H(a) |
H(b) |
H(c) |
H(d) |
| |
| (*) If additional "FH" abundance grading (as shown below) of the healed features is not applied/requested than it will say on the report: Abundance of healing features not graded.
|
GRS Clarity Enhancement grading (CE)* Abundance of Healed Fissures (FH = Fissure Healing), independent of amount of residues |
CE (FH): None |
CE(FH): Minor |
CE(FH): Moderate |
CE(FH): Prominent |
References: |
Peretti, A.. (1993): Foreign substances in Mong Hsu rubies. JewelSiam, Vol.4, No. 5, p. 42. |
Peretti, A. Schmetzer K., Bernhardt H.H. and Mouawad F. (1995): Rubies from Mong Hsu. Gems and Gemology, Vol 31, No.1, pp. 2-26. See Chapter Fracture Fillings Produced by Heat Treatment on pp.18-19.
|
| Other laboratories |
TE1 |
TE2 |
TE3 |
TE4 |
TE5 |
Enhancement Disclosure Policy Up until September 2004
 |
Not Treated |
RUBY AND SAPPHIRE TYPE OF TREATMENT |
| Disclosure policy |
A |
H |
H (a) or E |
H (b) or E |
H (c) |
H (d) |
| GRS GemResearch Swisslab |
No indication of thermal treatment No indication of thermal enhancement |
Enhanced by heat. Residue(s) not present. |
Enhanced by heat. Residue(s) insignificant. |
Enhanced by heat. Minor residue(s) present. |
Enhanced by heat. Residues present in fissures and cavities. |
Enhanced by heat. Significant residue(s) present in fissures and/or cavities. |
| Sample of an American Laboratory |
None, no indications of enhacement by heat |
Enhanced by heat(No residues present) |
Enhanced by heat |
| Minor amount of residue |
Moderate/significant amount of residue |
Treated Natural Ruby Glass is filling what would otherwise be small open cavities. |
| Gübelin Gem Lab * |
No indication of thermal enhancement. |
Indication of thermal enhancement. Minor/Moderate/Prominent solid residues present in fissure/cavities. (TE1 to TE6) |
| SSEF * |
No indication of thermal enhancement. |
Indication of thermal enhancement. |
Indications of thermal enhancement and artificially glassy residues in fissures. Extend of enhancement: Minor/Moderate/Prominent |
Treated |
| Federal Trade Commission (FTC) NY * |
|
.Disclosure is not required as long as the treatment is permanent and requires no special handling or care |
Disclosure is required |
| CIBJO * |
No comment.
|
Comment or disclosure statement is optional |
Disclosure statement is required stating the heat treatment and the presence of residue(s) |
Treated |
| Treatment Stability |
|
Enhancement permanent. |
Under investigation.
|
Enhancement requires special handling or care. |
* This data are compiled to the best knwoledge of GRS. The compilation in this summerized comparison is subjective. It is absolutely necessary that the laboratory referred to in this compilation is contacted for more detailed information directly, e.g. order their brochures or costumer information or use our provided link to contact them.
|